Information Name: | Mitsubishi generator maintenance | diesel generator (certified) | Greensboro generator maintenance |
Published: | 2015-01-13 |
Validity: | 0 |
Specifications: | Limited |
Quantity: | |
Price Description: | |
Detailed Product Description: | 1. How to extend the life of the new machine after Cummins generators installed, before starting from the seal should be checked before each boot, should be prepared "before starting preparation" occupation. Keep in mind that you must load starting diesel engine 2. Diesel induction generator must be constructed by the familiar unit, grasp the security personnel to manipulate manipulation rules for diesel new or overhauled, subject to application of 60 hours at the start of the run to run. 3. The new turbocharged diesel engine swap or new growth voltage regulator must remove the intake pipe fittings turbocharger diesel generator maintenance on, add 50 ~ 60mL of oil, to avoid starvation and burn at the start bearing turbocharger No license without air filtration start timer diesel engines, to avoid dust and impurities into the diesel generator maintenance, in order to avoid early wear of diesel engine. After 4 diesel engine starting, you should first load operation 3-5min Cummins generator maintenance, then gradually speed and load the license to be a diesel engine the water temperature is above 75 ℃, the oil temperature is above 50 ℃, when the oil pressure is higher than 0.25MPa, just go in a normal occupation license. 5. For new or perennial unused generators before running properly, you must go through a rigorous inspection The main examination situation winding insulation, wiring situation, etc., if inconsistent, hold the necessary treatment. 6. diesel run should always observe the operation of diesel engines for the state and all the indicated value of the instrument. In case of an emergency situation should adopt urgent measures to stop to avoid overheating due to lack of water or diesel engine oil pressure loss killed leaving. absolutely not allowed to direct seawater cooled diesel engine can be used in case of failure to restrain the temperature of the thermostat should be immediately renewed, shall not be demolished in the use and maintenance of diesel generators process, we will encounter many problems, has many years of practical experience in the technical staff of the problems encountered were analyzed as follows: filter maintenance: the diesel engine filters including air filter, fuel filter clean, fuel filter with water separator. The role of the air filter is to filter dust particles in the air, so that the air entering the engine compression cylinder clean to avoid early damage intake and exhaust and turbocharger piston damage. The role of the fuel filter is the diesel filter out impurities and dust particles to ensure the normal operation of the fuel injectors and fuel pump and extend its life. Effect with water separator fuel filter is to filter the fuel impurities and dust particles larger maintenance of large generators, diesel oil and water separation and precipitation after removal of diesel fuel in the water, in order to improve the quality of diesel fuel and prolong behind the fuel filtration life. Filtration efficiency fuel filters meet or greater than 90% filtration efficiency fuel filter with water separator is greater than 80%. If the presence of water and impurities diesel, fuel system components due to water or the like within the diesel rust and corrosion damage due to the presence of impurities, visible, water and filtered to remove impurities from the diesel fuel system failures and extend life is very important. Replace the fuel filter is based on a different fuel oil replacement cycle is different, when the replacement filter, the filter is full of clean diesel (Note: Carter EFI engine Cummins engine need not require), in Apply a little oil (15W / 40) on the filter gasket. Mitsubishi generator maintenance | diesel generator (certified) | Greensboro generator repair provided by Electrical Equipment Co., Ltd., Dongguan ShangXi firewood. Electrical Equipment Co., Ltd., Dongguan ShangXi Chai (www.dongguanfadianji.cn) is an industry leader in Dongguan, Guangdong, diesel generator sets, over the years, the company is implementing the scientific management, innovation and development, the principle of honesty and trustworthiness, and satisfy customer needs. On the diesel generator leadership with the staff warmly welcome all inquiries negotiations to create a better future for diesel generators. |
Admin>>>
You are the 20001 visitor
Copyright © GuangDong ICP No. 10089450, Electrical Equipment Co., Ltd., Dongguan ShangXi Chai All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 20001 visitor
Copyright © GuangDong ICP No. 10089450, Electrical Equipment Co., Ltd., Dongguan ShangXi Chai All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility